Anand Surgical Industries (India) Since 1974
267, Fie, Patparganj Industrial Area, Delhi
anand@anandsurgicals.com

Neonatal Products

Home – Neonatal Products

ASI-237

Baby Warmer

SKU: ASI-237 Category:

Description

Open care systems allow you to efciently care and provide advance warming capabilities while using one touch operations to simplify procedures. Advance microprocessor controlled system with self check on the electronic circuitry skin / air/ manual control.

Control Panel
Open care System comes complete with automatic manual and baby (Servo) modes. In addition, the Skin/Air temperature display is larger than other set temperature display. Skin temperature display can be converted form °C to °F by the push of button. A big LCD is provided for more information and visualizations of the heater power in manual and servo modes. A full complement of alarms provides safety and convenience, with both audible and visual indicators in the event of
• High Temp./ Low Temp. • System Fail • Probe Failure • Power Failure • Timer
• Heater fail / ON (Optional) only visual alarm provide

Heater Assembly
The heater assembly located above the centre of the support structure consists of an integral examination light and a 650 watts heating system (Silica or quartz /Ceramic Heater) for quick warming and even distribution of heat on the baby bed. The heater can be swivelled in either direction for taking X-ray and doing procedures.

Air Mode (Optional)
The system comes with air sensor. This is added security cover with exclusive feature of switching OFF the heater in case the AIR temperature goes above 39°C irrespective of what the skin temperature is at the time of event.

Manual Mode
The system automatically starts heating from 40% in manual mode and the same can be changed through settings up to 100%. The system automatically converts from servo mode to manual mode in case of probe failure thus providing nonstop working of the unit.

Baby Bed
The spacious baby bed incorporates easy drop down/fold down glasses for maximum access to the patient. Optional : X-Ray facility is provided below the baby bed for taking X-ray of the baby without disturbing.

The First Breath
The open care system combines virtually all the technology a caregiver may need in situation needed for resuscitation. The neonate can be supplied with a constant oxygen ow through the oxygen humidier when connected to an oxygen cylinder/wall unit. The motorized slow suction can be used with a simple ip of a switch. A digital apgar time is standard, which signals when 1, 5 and 10 minutes have elapsed.

Castors
The system is tted with 4″ high quality castors having brakes in front 2 castors.
Optional : antistatic castors

Storage
The unit comes tted with two drawer system which slides out for keeping consumables.

Phototherapy Unit (Optional)
The unit can be tted with LED phototherapy unit or CFL under surface phototherapy unit

Additional Features
If needed the unit can be programmed by the user himself for any of the following features:
(a) Count Up/down Timer. (b) Check baby Alarm. (c) Pre warming mode

ASI-238

Baby Warmer

SKU: ASI-238 Category:

Description

Advance micro processor controlled system with self check on the electronic circuitry Skin / Manual control. Digital Display of Baby Temperature / Set Temperature. Manual / Servo two function control modes provide the clinician more Fexibility while optimizing the thermal environment. The Spacious baby bed incorporated easily drop down sides for maximum access to the baby. The Control Panel is also the heart for a completely integrated alarm system with both audible and visual Indicators in the event of
• Probe Fail • Skin High • Skin Low • Power Fail

Manual Mode
Facility of converting the warmer from servo mode to manual mode for non-stop working. The heat in the manual mode is locked at 50% to give more protection for the baby.

Heater Assembly
The Heater assembly located above the center of the support structure consists of radiant heater and reector with inbuilt LED
examination lamp for assessment of Infant color. The heater can be swivelled to either direction.

Baby Bed
The attached spacious baby bed incorporates easy drop down glasses for maximum access to the patient.

Castors
The system is tted with 2″ high quality castors having brakes in front 2 castors. Antistatic castors can be tted as on option for further safety in lieu of the standard castors.

Dimensions(Approx.)
Technical Specication
Height – 1920mm
Length – 890mm
Width – 860mm

Electrical Specifications
Power Supply 220V/50Hz
Heater Power 650 Watts Fuse 5 Amp

OPTIONAL
2 Trays below the baby bed for keeping consumables.
2 Drawers tted below the baby bed.
LED Phototherapy below baby bed

ASI-239

Photo Therapy Single Surface

SKU: ASI-239 Category:

Description

  • Single Surface LED Phototherapy
  • LED 9-12 hi power,
  • Irradiance >42mw/cm2/nm at 30cm.
  • Light Source lifetime approximate 25,000 hrs,
  • Wavelength 420-480nm,
  • Variation in intensity for 6 hours<10%
  • Effective area 50cm x 30cm

ASI-240

Photo Therapy Double Surface

SKU: ASI-240 Category:

Description

  • Double Surface LED Phototherapy unit with baby bassinet
  • LED 9-12 hi power in overhead panel, and LED 9-12 hi power in
    undersurface panel
  • Irradiance >42mw/cm2/nm at 30cm.
  • Light Source lifetime approximate 25,000 hrs,
  • Wavelength 420-480mm,
  • variation in intensity for 6 hours<10%
  • Effective area 50cm x 30cm